| Specifications
Specification Details For ANTRACK
Product Glance | |
Model | ANTRACK |
Version | V1 |
Capacity | 4 units ANTMINER (S21 Hyd.) |
Maximum load,kW | 24 |
Detailed Characteristics | |
Hardware configuration | |
Size (Width*Height*Depth),mm | 600*2000*1000 |
Net weight, kg | 300 |
Network connection mode | EJ45 Ethernet 10/100M |
Power Supply | |
Power supply AC Input voltage, Volt(1-1) | 380~415 |
Power supply AC Input Frequency Range, Hz | 50~60 |
Power supply AC Input current, Amp(1-2) | 80 |
Environment requirements | |
Ambient temperature, °C | 15~45 |
Water flow, L/min | 32.0~40.0 |
Water pressure, bar | ≤3.5 |
Working fluid(1-3) | Deionized water/Pure water |
Liquid PH | 8.5~9.5 |
Storage temperature, °C | -20~70 |
Operation humidity(non-condensing), RH | 10~90% |
NOTE:
(1-1) Caution: Wrong input voltage may probably cause miner damaged
(1-2) Three-phase AC input.
(1-3) If the water conductivity is ≥100 μs/cm, the fluid must be replaced. The water conductivity is less than 20 μs/cm when the system is running at the first time.